Sichuan ULUPURE Ultrapure Technology Co., Ltd.

Technical Requirements for Lead-Acid Battery Electrolyte

Table of Content [Hide]

    The electrolyte is prepared by mixing concentrated sulfuric acid with purified water (deionized or distilled water). It must be prepared using battery-specific sulfuric acid conforming to national standard GB4554-84, mixed with qualified purified water to achieve an electrolyte density of 1.22±0.01 g/cm³ (20℃).


    Sulfuric Acid Standard for Lead-Acid Batteries GB4554-84


    Serial Number

    Indicator Name

    dilute sulfuric acid

    concentrated sulfuric acid

    Level 1

    Level 2

    Level 1

    Level 2

    1

    Sulfuric acid ( H₂SO₄ ) content, %

    60

    60

    92

    92

    2

    Residue on ignition content, % ≤

    0.2

    0.035

    0.03

    0.05

    3

    Manganese (Mn) content, % ≤

    0.000035

    0.000065

    0.00005

    0.00001

    4

    Iron (Fe) content, % ≤

    0.0035

    0.008

    0.005

    0.012

    5

    Arsenic (As) content, % ≤

    0.000035

    0.000065

    0.00005

    0.00001

    6

    Chlorine (Cl) content, % ≤

    0.00035

    0.00065

    0.0005

    0.0001

    7

    Nitrogen oxides (calculated as N) content, % ≤

    0.000065

    0.00065

    0.0001

    0.001

    8

    Ammonium ( NH4 ) content, % ≤

    0.00065


    0.001


    9

    Sulfur dioxide (SO2)

    Content, % ≤

    0.0025

    0.0045

    0.004

    0.007

    10

    Copper (Cu) content, % ≤

    0.00035

    0.0035

    0.0005

    0.005

    11

    Reduced potassium permanganate content, % ≤

    0.00065

    0.0012

    0.001

    0.002

    12

    Colorimetric intensity, ml ≤

    0.65

    0.65

    1.0

    2.0

    13

    Transparency, mm ≥

    350

    350

    160

    50


    Water Standards for Lead-Acid Batteries (Draft National Professional Standard for Approval) For Reference


    Serial Number

    Indicator Name

    index

    %

    mg/l

    1

    Appearance

    colorless

    transparent

    2

    Residue content ≤

    0.01

    100

    3

    Manganese content ≤

    0.00001

    0.1

    4

    Iron content ≤

    0.0004

    4

    5

    Chlorine content ≤

    0.0005

    5

    6

    Nitrate (as N) content ≤

    0.0003

    3

    7

    Ammonium content ≤

    0.0008

    8

    8

    Reduced potassium permanganate content, % ≤

    0.0008

    2

    9

    Alkaline earth metal oxide (calculated as CaO) content ≤

    0.005

    50

    10

    Resistivity (25℃) Ω ·cm ≥

    10 × 10⁴


    References
    ULUPURE