Requirements:
The main performance indicators of the equipment, including water production capacity, filtration accuracy, and filtration efficiency, should meet the designed rated values.
The structure of the equipment should be reasonable and compact.
All components used in the equipment, such as membrane elements, pumps, pipe fittings, valves, and instruments, should conform to relevant standards or specifications.
For equipment used in drinking water treatment, the materials in contact with water should conform to GB/T17219.
The equipment frame should be firmly installed, with smooth welds. If painted, the coating should be uniform.
The equipment's piping should be installed straight, rationally laid out, and leak-free. Metal pipe installation and welding should conform to GB 50235, and pipe installation and connections should conform to HG 20520.
The electrical control components of the equipment should operate reliably.
The pumps of the equipment should be installed stably and firmly, and there should be no abnormal vibration during operation.
The electrical safety of the equipment should conform to GB 4706.1.