    When is disinfection needed?

    How to disinfect and what chemicals to use for disinfection


    Bacterial control and sterilization

    Rules for controlling bacterial concentration in concentrated water:

    • If <4 log CFU/mL, the bacterial count is considered under control.

    • If 4 to 6 log CFU/mL, attention should be paid.

    • If 6 log CFU/mL is reached or the bacterial count increases, the problem should be addressed.


    Note: 4 log = 10,000 = 10⁴ 6 log = 1,000,000 = 10⁶


    • Disinfection: refers to a 99.9% reduction in bacteria (3 logs)

    • Sterilization: refers to a 99.9999% reduction in bacteria (6 logs)

    • Sterilization: refers to a 99.9999999% reduction in bacteria (9 logs)

    • Bioinhibitors: inhibit bacterial growth

    • Slime destroyers: destroy the biofilm


    Characteristics of reverse osmosis chemical sterilization


    • Kills bacteria

    • Removes biofilm

    • Minimal contact time

    • Minimal harm to membranes

    • Non-toxic and environmentally friendly

    • Safe to operate

    • Reasonable price


    What are some disinfectants for disinfecting reverse osmosis composite membrane elements?


    Formaldehyde


    • Dosage: 0.1~1.0%

    • In the United States, this agent is considered to have some toxicity.

    • For new membranes, it must be used only after 24 hours of operation, otherwise it will lead to irreversible water flux loss.

    • Can be used as a disinfectant solution that can be stored for a long time.


    Sodium bisulfite


    • Dosage: 500ppm, use 30~60ppm

    • A 1.0% solution can be used for long-term storage.


    Isothiazolinone


    • Dosage: 15~25ppm

    • Can be used as a disinfectant solution for long-term storage.


    Hydrogen peroxide/peracetic acid


    • Dosage: 0.2% (sum of the two compounds)

    • pH: 3~4 (high pH values will cause membrane oxidation)

    • Temperature: 25℃ (maximum)

    • The presence of iron or excessive metals can cause CPA membrane oxidation.

    • Circulate repeatedly for 20-30 minutes / soak for 2 hours / then rinse.

    • A contact time of up to 4 hours may be required to disrupt biofilms.

    • It is an effective and rapid oxidizing bactericide.

    • It is relatively effective in disrupting biofilms.

    • This bactericide is not suitable for long-term storage.


    KY-221


    • Dosage: 50 PPM (shock sterilization)

    • Dosage: 0.5 PPM (continuous sterilization)

    • Non-oxidizing bactericide, with rapid and effective sterilization.

    • It has a good stripping effect on bacterial slime.

    • Compatible with all membrane elements.

    • Wide operating pH range, good biodegradability, and environmentally friendly.

    • 30 minutes each time, once every two weeks, is sufficient for good results.

    • Can be added during normal operation without stopping the system.

    • KY-221 reverse osmosis-specific bactericide can also be used as a shutdown cleaning agent for reverse osmosis systems.

    • Suitable for long-term storage disinfection.


    Note: This product is developed, researched, and produced by Kaiyuan Hengye.


    Acetic Acid Film Disinfectant


    Free Chlorine


    • Dosage: When the pH is 5-6, add continuously at a dose of 0.1-1.0 ppm.

    • Dosage: Once every two weeks, use 5 ppm for 1 hour each time.

    • Reaction with corrosion products (iron) may cause abrasive damage.

    • If iron is present, it is recommended to use a chloramine solution with a maximum concentration of 10 ppm instead.

    • A solution of 0.1-1.0 ppm can be used as a disinfectant for long-term storage.


    Formaldehyde


    • Dosage: 0.1-1.0%

    • Can be used as a disinfectant for long-term storage.


    Isothiazolinone


    • Dosage: 15-25 ppm

    • Can be used as a disinfectant for long-term storage.


    KY-221


    • Dosage: 50 PPM (shock disinfection)

    • Dosage: 0.5 PPM (Continuous Sterilization)

    • Non-oxidizing bactericide, providing rapid and effective sterilization.

    • Excellent removal effect on bacterial slime.

    • Compatible with all membrane elements.

    • Wide operating pH range, good biodegradability, and environmentally friendly.

    • 30-minute dosing every two weeks is sufficient for good results.

    • Can be added during normal operation without system shutdown.

    • KY-221 reverse osmosis-specific bactericide can also be used as a shutdown cleaning agent for reverse osmosis systems.

    • Can be used as a sterilizing solution for long-term storage.


    Note: This product was developed, researched, and manufactured by Kaiyuan Hengye.